Owner’s manual, Cleaning and maintenance, Technical service specifications – Desa CGP10TA User Manual

Page 13: Service hints service publications, Accessory

Advertising
background image

13

104268

OWNER’S MANUAL

CLEANING AND
MAINTENANCE

ODS/PILOT AND BURNER
ORIFICE

• Use a vacuum cleaner, pressurized air,

or small, soft bristled brush to clean.

CLEANING BURNER
PILOT AIR INLET HOLE

We recommend that you clean the unit every
2,500 hours of operation or every three months.

We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store, or
home center may carry compressed air in a
can. You can use a vacuum cleaner in the
blow position. If using compressed air in a
can, please follow the directions on the can.
If you don't follow directions on the can, you
could damage the pilot assembly.

1.

Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.

2.

Inspect burner, pilot for dust and dirt.

3.

Blow air through the ports/slots and
holes in the burner.

Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 22). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabinet
to remove dust.

You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-323-5190.

You can also visit DESA International’s
technical service web site at

www.desatech.com.

TECHNICAL
SERVICE

SPECIFICATIONS

CGP10TA/CGP10TLA

Btu (Variable)

5,000/10,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Regulator Setting

8" W.C.

Inlet Gas Pressure (inches of water)

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

Heater (Including knobs and grill)

21

1

/

2

x 13

1

/

2

x 7

Carton

25

1

/

4

x 16

3

/

4

x 7

1

/

2

Weight (pounds)

Shipping

19

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

When Gas Quality Is Bad

• pilot will not stay lit

• burner will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.

SERVICE
HINTS

SERVICE
PUBLICATIONS

You can purchase a service manual from the
address listed on the back page of this
manual. Send a check for $5.00 payable to
DESA International.

ACCESSORY

Purchase these heater accessories from your
local dealer. If they cannot supply this ac-
cessories, either contact your nearest Parts
Central or call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.

EQUIPMENT SHUTOFF
VALVE - GA5010

Equipment shutoff valve with 1/8" NPT tap.

Figure 22 - Pilot Inlet Air Hole

Pilot Assembly

Pilot Air Inlet Hole

Advertising