Vent-free propane/lp gas heater, Troubleshooting, Continued – Desa CGP10TA User Manual

Page 16

Advertising
background image

16

104268

VENT-FREE PROPANE/LP GAS HEATER

WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

TROUBLESHOOTING

Continued

IMPORTANT:

Operating heater where impurities in air exist may create odors.

Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new
carpet or textiles, etc., create fumes. These fumes may mix with combustion air and
create odors.

OBSERVED PROBLEM

Heater produces a clicking/ticking noise
just after burner is lit or shut off

Heater produces unwanted odors

Heater shuts off in use (ODS operates)

Gas odor even when control knob is in OFF
position

Gas odor during combustion

Moisture/condensation noticed on windows

REMEDY

1. This is common with most heaters. If

noise is excessive, contact qualified ser-
vice person

1. Ventilate room. Stop using odor-causing

products while heater is running

2. Refill supply tank
3. Locate and correct all leaks (see Check-

ing Gas Connections, page 10)

1. Open window and/or door for ventilation
2. Contact local propane/LP gas company
3. Clean ODS/pilot (see Cleaning and

Maintenance, page 13)

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 10)

2. Replace control valve

1. Take apart gas tubing and remove for-

eign matter

2. Locate and correct all leaks (see Check-

ing Gas Connections, page 10)

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

POSSIBLE CAUSE

1. Metal expanding while heating or con-

tracting while cooling

1. Heater burning vapors from paint, hair

spray, glues, etc. See

IMPORTANT

statement above

2. Low fuel supply
3. Gas leak.

See Warning statement at

top of page

1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged

1. Gas leak.

See Warning statement at

top of page

2. Control valve defective

1. Foreign matter between control valve

and burner

2. Gas leak.

See Warning statement at

top of page

1. Not enough combustion/ventilation air

www.desatech.com

Advertising