EXFO FastReporter Data Post-Processing Software User Manual
Page 116

Working with iOLM files
110
FastReporter
Viewing and Modifying iOLM Thresholds
3. In the Results window, select the Thresholds tab.
4. Select the wavelength for which you want to view or modify the Link
Pass/Fail thresholds and Element Pass/Fail thresholds values. You can
select more than one using the Ctrl or Shift keys.
5. Under Link Pass/Fail thresholds, modify the thresholds associated
with the wavelengths needed by clicking in the desired threshold value
and modifying it in the table. The Apply option must be enabled for the
threshold to be active and editable.
Note: If you have selected more than one wavelength, all of them will be
modified at the same time.
6. Under Element Pass/Fail thresholds, modify the thresholds associated
with the wavelengths needed by clicking in the desired Element
Pass/Fail threshold value and modifying it in the table. The Apply
Pass/Fail option must be enabled to modify and apply all the Element
Pass/Fail thresholds values.
7. Select the splitter ratio from the Splitter ratio field to view or modify
respective Maximum splitter loss value.