EZ-ACCESS PASSPORT User Manual

Page 15

Advertising
background image

Page 15 of

26

h. Verify the platform and the top landing levels are within 1/2

” of each other.

If the platform and the top landing levels are not within 1/2” of each other, do not attempt to
exit the VPL at this time. Raise or lower the VPL until the top landing levels are not within

1/2”

of each other before exiting the platform. If the problem persists, contact you dealer to
schedule any needed inspections, repairs or service.

If desired, you can now turn the VPL keyed power switch key to the Power Off position prior
to exiting

i. Turn the power back on to your mobility device, release the mobility device brakes and travel off the

Platform onto the upper landing.

If your installation includes the optional Top Landing Gate: Once the Platform has reached
the upper landing, the Top Landing Gate will automatically unlatch, allowing the gate to open.
The Top Landing Gate is spring loaded and will close by itself once you have passed
through.

3. DOWNWARD TRAVEL:

a. If the platform is in the upper landing position the optional Top Landing Gate should swing open by

pulling on it. If the Top Landing Gate does not swing open freely this could be an indication that the
VPL platform may not be at the required height.

The platform must be properly positioned at the upper landing height before the VPL gate can
be operated.

Do not attempt to release the Top Landing Gate latching mechanism manually.

b. Open the Top Landing Gate and carefully travel onto the platform. Travel far enough that the

mobility device and all body parts are completely on the VPL platform and the Top Landing Gate
will close fully and latch.

c. Turn off power and ensure the brakes are securely set on the mobility device. (Contact

manufacturer of your particular mobility device for assistance).

d. Rotate the keyed power switch to Power On position. The blue LED indicator light in the GREEN

background should now be illuminated.

e. Press and hold the DOWN button. The VPL will begin moving in the downward direction and the

DOWN indicator light will be illuminated.

f. Continue pressing the DOWN button until the VPL stops automatically at the lower landing. The

ENTER/EXIT indicator LED light will now illuminate. Release the DOWN button.

g. Verify the guard ramp has folded to the down position and is resting on the lower landing surface.
h. Turn the power back on to your mobility device, release the mobility device brakes (contact the

manufacturer of your particular mobility device for assistance) and travel off the Platform onto the
lower landing.

Advertising