B) (c) (d), 15 routine cleaning and inspection – Glow-worm 23c User Manual
Page 23
Advertising
23
2000225000B
15 Routine Cleaning and Inspection
Diagram 15.3
9976
Diagram 15.4
9977
Diagram 15.2
9836
(b)
(c)
(d)
HEATING
RETURN
COLD
WATER IN
HEATING
FLOW
Note: Isolating cocks water and gas
are shown in the: OFF position
To Drain the Domestic hot water circuit
• Close boiler isolating valve (c).
• Turn on one or more hot water taps.
To Drain the boiler
• Close isolating screws on the isolating valves (b), (c) and (d) turn from vertical
to horizontal to close.
• Open the boiler drain valve (a).
• Turn on one or more hot water taps.
(a)
BOILER DRAIN VALVE
9839