1 technical data, Heating, Hot water – Glow-worm 23c User Manual

Page 8: Natural gas (g20) electrical, Combustion

Advertising
background image

8

2000225000B

1 Technical Data

Heat input (max) NET Q

25 kW

85,300 BTU/H

Heat input (min) NET Q

10,4 kW

35,490 BTU/H

Heat output (max) NET P

23 kW

78,480 BTU/H

Heat output (min) NET P

8,7 kW

29,670 BTU/H

Efficiency - Sedbuk D

79,90%

Maximum heating temperature

87° C

Expansion vessel effective capacity

5 l

Expansion vessel charge pressure

0,5 bar

Maximum system capacity at 75°C

110 l

Safety valve,

maximum service pressure 3 bar

Ø Burner injector

1,2 mm

Inlet pressure

20 mbar

Maxi. Burner pressure

12 mbar

Mini. Burner pressure

2 mbar

Gas rate maximum

2,64 m

3

/h

Heating

Heat input (max) NET Q

25 kW

85,300 BTU/H

Heat input (min) NET Q

10,4 kW

35,490 BTU/H

Heat output (max) NET P

23 kW

78,480 BTU/H

Heat output (min) NET P

8,7 kW

29,670 BTU/H

Maximum hot water temperature

63 °C

Minimum hot water temperature

35 °C

Specific flow rate

(for 30°C temp rise)

11L/min.

Threshold flow rate

1,7 L/min.

Maximum supply pressure

10 bar

Minimum supply pressure

0,5 bar

Hot water

Electrical supply

230 V ~ 50Hz

Electrical rating

122 W fused at 3A

Level of protection

IPX4D

Fuse rating

125mA

Natural Gas (G20)

Electrical

Products outlet diameter

60 mm

Fresh air inlet diameter

100 mm

Combustion products values

CO (52 ppm)

CO2 (6,40%)

NOx (92ppm)

Combustion