4 Installation

IMPORTANT: Use hard solder only, soft solder is NOT

suitable.
Do not use any plastic pipes.
Flexible stainless steel pipes supplied by Glow-worm or

copper pipes should be used for the solar circuit.
Optional Glow-worm flexible pipes for the connection of the

collectors to the solar pump unit.
0020054994: 2 in 1 flexible pipe DN 16 x 15 m
0020054964: single flexible pipe DN 16 x 15 m
Two single flexible pipes DN 16 x 15 m are available as part

of the Glow-worm optional pipework kit. Instructions for the

connection of these flexible pipes can be found in separate

installation instructions.
Due to the occasionally high temperatures of the solar fluid,

plastic pipes must not be used for the solar circuit. Copper

pipes must be joined using hard soldering or compression

fittings. Soft soldering is NOT suitable.
Teflon tape can be used on pipework below the Solar Pump

Station.
IMPORTANT: Earth the solar circuit!

The solar pipework must be earthed in accordance with the

requirements of BS 7671 IEE Wiring Regulations. Wiring

protection should be provided if there is high risk of lightning

strikes. The electronics in the solar system, heating system or

in the house could otherwise be destroyed if they were to be

hit by lightning. Connect the collectors to an existing lightning

protection on the house.
IMPORTANT: Risk of damage to the collectors due to

excessive pressure. The installation of a motorised 2 port

valve in the pipes of the solar system is not allowed, since the
safety devices in the solar circuit could be overridden by it.
The right selection of the pipe diameters plays a significant

role in terms of maximum efficiency of the solar system.
To keep the pressure loss in the solar circuit to a minimum,

the flow velocity in the copper pipe should not be higher than

1.5 m/s.
A nominal flow rate of 0.66 l/min per net m

2

collector surface is

required by the collectors to achieve optimum heat transfer.
Another decisive criteria for the optimum operation of your

solar system is the speed of the solar pump. The pump must

be able to deliver more than the nominal flow rate at the

specified operating pressure. The selection of the required

pump speed depends on the installed system. Reference

value for the pump selection can be found in section 5.2.
Connections to solar pump station
IMPORTANT:
An air separator is required - refer to diagram

4.5.
Using the compression fittings supplied with the pump station,

connect the pump station ‘flow’ assembly to the collector flow

pipe and the pump station ‘return’ assembly to the collector

return pipe.

IMPORTANT: ensure the collector pipes are

connected correctly - the pump station ‘return’ assembly

includes the pump.
Use the fittings included to connect to 22mm copper pipes.
Again using the compression fittings supplied with the pump

station, connect the pump station ‘flow’ assembly to the

cylinder ‘solar circuit flow’ connection then the pump station

‘return’ assembly to the cylinder ‘solar circuit return’.

4.2 Fitting the solar pump station

(wall-mounted installation)

Fit the wall bracket and the pump station flow and return

assemblies.
Secure the assemblies in the wall bracket using the two C-

clips. Put them onto the flow and return assemblies below the

wall bracket.

4.3 Pressure relief valve and expansion vessel

Fit the pressure relief valve assembly to the connection nozzle

in the pump station return tube assembly.
IMPORTANT: Loss of solar fluid! Install a discharge pipe from

the pressure relief valve outlet to a container to ensure that

any hot solar fluid escaping from the system is contained.
The solar fluid container is intended as a collecting container

when the system is filled and the container is empty. Connect

a discharge pipe from the relief valve outlet to the intended

location for the container.
Mount the expansion vessel wall bracket using screws and

plugs. Screw the flange and the expansion vessel to the wall

bracket.
The expansion vessel must be mounted vertically and the flow

from the system must enter the vessel from the top. To avoid

accidental spillage or access by children to the fluid, best

practice is to take the discharge pipe right to the bottom of

(but not touching) the container.
The empty solar fluid container is recommended, as re-

using it helps to reduce landfill, the contents of the container

are visible (you must be able to see if the safety valve has

discharged) and offers a practical solution. However, if

preferred, an alternative vessel may be used, provided it is

of adequate size, the contents are visible and it is not fully

sealed.

4.4 Notes on the solar circuit pipework

When installing solar circuit pipework between the collector

array and the cylinder, carefully consider the location of

the pump station and the requirement for an automatic air

separator. The Glow-worm solar system is a closed hydraulic

system in which heat can only be transferred to the cylinder

by means of special heat transfer fluid in the solar system.

Observe the following points to ensure perfect operation with

maximum energy utilisation:
Bleed the system completely during commissioning and

servicing since air in the system has a considerable effect on

the efficiency.
The pipe diameters should not be too large, otherwise the

the flow in the solar system will slow down, reducing the

efficiency.
Lay all system components in such a way to ensure an even

flow at the required nominal flow rate.
Provide sufficient thermal insulation of the pipes to prevent

excessive heat loss. The insulation must withstand

temperatures up to 150°C. Select weather and UV resistant

insulation which is “bird peck proof“ especially for pipes laid

outside.
When using compression fittings, you must consult the

manufacturer of these fittings to check their suitability for solar

systems.
Use compression fittings only if temperatures of up to 200°C

are allowed by the manufacturer.