5 flat surface installation - vertical collector, 3 collector installation – Glow-worm Clearly Solar - A-Frame User Manual

Page 12

Advertising
background image

12

Diagram 5.2

14999

Diagram 5.3

14933

Diagram 5.4

14934

5 Flat Surface Installation - Vertical Collector

5.3 Collector Installation

NOTE: Roof installation

With due regard to the complete weight of the ballast, frame,

collector and system, proceed as follows:

With the floor section secured (screwed or gravel trays) to the

flat surface, fix the lower telescopic section with retaining pin

and safety clip, see diagram 5.2.

NOTE: If gravel trays are used, slide the gravel tray onto the

floor section before fixing the lower telescopic section, see

diagram 5.3.

Apply the safety clamps from the top floor sections (2x frame)

to fix the gravel tray.

Collectors should have 3 gravel trays per frame.

Extend the telescopic sections until the hole of the desired

position is aligned, then secure with retaining pin and safety

clip, see diagram 5.4.

You can choose 30º, 45º or 60º, the standard is 45º.

SAFETY

CLIP

RETAINING

PIN

SAFETY

CLAMPS

GRAVEL

TRAY

RETAINING

PIN

SAFETY

CLIP

FLOOR

SECTION