5 flat surface installation - vertical collector, 3 collector installation – Glow-worm Clearly Solar - A-Frame User Manual
Page 12
12
Diagram 5.2
14999
Diagram 5.3
14933
Diagram 5.4
14934
5 Flat Surface Installation - Vertical Collector
5.3 Collector Installation
NOTE: Roof installation
With due regard to the complete weight of the ballast, frame,
collector and system, proceed as follows:
With the floor section secured (screwed or gravel trays) to the
flat surface, fix the lower telescopic section with retaining pin
and safety clip, see diagram 5.2.
NOTE: If gravel trays are used, slide the gravel tray onto the
floor section before fixing the lower telescopic section, see
diagram 5.3.
Apply the safety clamps from the top floor sections (2x frame)
to fix the gravel tray.
Collectors should have 3 gravel trays per frame.
Extend the telescopic sections until the hole of the desired
position is aligned, then secure with retaining pin and safety
clip, see diagram 5.4.
You can choose 30º, 45º or 60º, the standard is 45º.
SAFETY
CLIP
RETAINING
PIN
SAFETY
CLAMPS
GRAVEL
TRAY
RETAINING
PIN
SAFETY
CLIP
FLOOR
SECTION