9 flat surface installation - horizontal collector, 5 collectors – Glow-worm Clearly Solar - A-Frame User Manual

Page 25

Advertising
background image

25

9 Flat Surface Installation - Horizontal Collector

Diagram 9.9

15157

PIPE

COUPLING

SECURING

CLIP

Remove the plugs from the openings of the collector and

insert the pipe couplings up to their stops, see diagram 9.9.

Slide the retaining clips into place to secure the pipe

couplings.

NOTE: The collector design is symmetrical and does not have

a top or bottom.

Place the next collector on the lower mounting rail and slide

towards the first collector.

Secure the pipe couplings to the second collector with the

securing clips.

Tighten the clamping assemblies of the first collector with the

socket/ combination wrench (SW13), see diagrams 9.10 and

9.11.

With regards to the hydraulic system you have chosen, insert

and secure the hydraulic connections, see diagram 9.10.

Insert the collector sensor into the appropriate elbow (flow,

top), see diagram 9.10. The collector sensor is packed with

the Fluropro controller, part no. 0020054960.

Mount the plug with the bleed valve (vent) in the opposite top

position.

Diagram 9.10

15158

FLOW

ELBOW

(with sensor)

SECURING

CLIP

RETURN

ELBOW

(inlet)

SECURING

CLIP

SECURING

CLIP

UPPER PLUG

WITH VENT

SECURING

CLIP

LOWER PLUG

TOP AND BOTTOM OR DIAGONAL FLOW

1-5 Collectors

Advertising