5 single collector flashing kit - 22 – Glow-worm Clearly Solar Horizontal In-Roof Collector User Manual
Page 14

14
No.1
No.5
Diagram 5.13
15125
TILE BAR
TILE BAR
STRAP
Fix the ridge plates to the roof battens with the screws (No. 1)
using the supplied Torx bit.
Fix the ridge plate coupling to the ridge plate joint with three
screws (No. 5) using the supplied Torx bit, see diagram 5.12.
5.3 Tile Bars
Place the tile bars on the ridge plates.
Bend the metal bands and hook the tile bars to the roof batten
from the top, see diagram 5.13.
5.4 Covering the profile ends
Cover the side profile ends and the collector joints with the
profile end pieces, see diagram 5.1 for profile end location.
Fit the profile end pieces to the bottom of the collector edge
and then tilt them up, until they lock in the upper collector
edge, see diagram 5.14.
Diagram 5.14
14981
PROFILE END PIECE
COLLECTOR
EDGE
5 Single Collector Flashing Kit - 22
0
- 75
0
Diagram 5.12
15147
RIDGE PLATE
COUPLING