Scope of delivery

Pack contents
1

Collecting container for solar application

(1)

2

Drain valve with protective cap

(1)

3

bolts and wall plugs

(2)

•

Please check the contents of packs.

5.2

fitting the collecting container

5.2.1

Securing the collecting container to the wall

160

•

Drill two holes, 160mm apart, into a load bearing wall.

•

Secure the collecting container to the wall using wall plugs and bolts

which are suitable for the type of wall.

•

Check that the drain valve is closed and the sealing cap is attached.

5.3

Connecting the collecting container

2

3

1

4

Key:

1 Outlet side of the expansion relief valve

2 Collecting tank

3 Expansion vessel for solar application with auxiliary vessel

4 Solar pump unit

•

Connect a heat-resistant pipe to the outlet side of the expansion relief

valve, see 2.3 Hydraulic schematic, no. 1.

•

Always lay the pipe so that it slopes down to the collecting container.

1

Key:

1

Opening for the discharge line

•

Guide the free end of the pipe at least 10cm into the plastic bushing of

the upper opening on the collecting container.

5.4

filling/draining the collecting container

5.4.1

filling the collecting container

•

Fill the collecting conntainer with 1 litre (basic filling level) of frost-

resistant liquid in order to prevent the container from overheating

when the expansion relief valve is triggered.

Advertising