Installation – Glow-worm Clearly Solar Collector Container User Manual

Page 7

Advertising
background image

0020147746_00 - 03/12 - Glow-worm

- 5 -

INSTAllATION

EN

5.4.2

Draining the collecting container

The collecting container must be drained after the expansion relief valve

has been triggered.

Make sure that the solar fluid has cooled down before you drain the

collecting container.

Remove the safety cap from the expansion relief valve.

Drain the collecting container into a vessel that is suitable for solar

fluid.

Dispose of the removed solar fluid correctly.

5.5

Maintenance

At least once a year, check that the collecting container's basic filling

level (1 litre) is correct.

5.6

Notes on the piping system

a

DANGER:

Risk of personal injury and material damage due to escaping

hot solar fluid!

Hot solar fluid can damage plastic pipes and consequently

escape.

- Use copper pipes.

Caution:

Press fittings that are not temperature resistant may damage

the solar energy system! Press fittings must be designed for

temperatures up to 200

o

C - otherwise, the press fittings may

start to leak.

- Ask the manufacturer of the press fittings whether the press

fittings are solar resistant.

6

Handing over to the operator

You must inform the operator of the unit about the handling and function

of their collecting container.

Provide the operator with all relevant instructions and unit

documentation for safe-keeping.

Go through the operating instructions with the operator.

Answer any questions the operator may have.

Draw special attention to the safety information which the operator

must follow.

Inform the operator of the necessity to ensure that the system

is regularly inspected/maintained (inspection and maintenance

contract).

Make the operator aware of the need to keep the instructions near the

collecting container.

7

Customer service

Servicing/maintenance should be carried out by a competent person

approved at the time by the Health and Safety Executive in accordance

with the rules in force in the countries of destination.

To obtain service, please call your installer or Glow-worm's own service

organisation on Tel: 01773 828100.

Advertising