7

221564F

1 General Information

Diagram 1.2

■ For larger systems use an additional expansion vessel.

● Ball valves are fitted in water and gas connections, plus a drain point on all water connections.

80

100

Lift Weight

72kg (158.7lb) 77kg (169.7lb)

Total Weight (packed)

76kg (167.5lb) 81kg (178.6lb)

Total Weight (installed)

94kg (207.2lb) 99kg (218.3lb)

Gas connection

Rc

1

/

2

(

1

/

2

in BSPT)

Heating and return

22mm compression

Domestic hot water

15mm compression

Safety valve

Preset 3bar (43.5lbf/in

2

)

Safety valve discharge

15mm copper

80

100

Water content (heat exch)

2.7 ltr (0.59 gall) 4 ltr (0.88 gall)

Water content (primary store)

13 ltr (2.86 gall) 12.4 ltr (2.7 gall)

Water content (domestic)

1.3 ltr (0.29 gall) 2 ltr (0.44 gall)

Expansion vessel capacity 7 litres (1.54 gallons)

Charge pressure

0.5bar (7.3lbf/in

2

)

Heating system

0.7bar (10.1lbf/in

2

)

minimum pressure

Domestic hot water flow rate

80

100

temp rise 30

0

C 11.4l/min (2.5gall/min) 13.3l/min (2.9gall/min)

35

0

C 9.8l/min (2.2gall/min) 11.4l/min (2.5gall/min)

Maximum flow temperature

65

0

C

Minimum working pressure

0.1bar

Maximum heating

130 litres

system water

(28.6 gallons)

content using

at 75

0

C

fitted expansion

average system

vessel, pressurised

temperature

at 1bar.

Electrical supply

230V~50Hz

Electrical rating

115W fused 3A

TABLE 2

6499

NOMINAL kW

80 27.5 27.5 8.0

HEAT Btu/h 93,830 93,830 27,266
INPUT kW

100 32.5 32.5 10.2

GROSS Btu/h 110,890 110,890 34,802

NOMINAL kW

80 24.5 24.5 6.8

HEAT Btu/h 83,600 83,600 23,200
OUTPUT kW

100 28.8 28.8 8.9

Btu/h 98,266 98,266 30,367

COND. kW

80 25.5 25.5 7.7

HEAT Btu/h 87,000 87,000 26,170
OUTPUT kW

100 30.5 30.5 9.8

Btu/h

104,066 104,066 33,438

BURNER

mbar

80 -4.5 -4.5 -0.5

MANIFOLD

wg

-1.8 -1.8 -0.2

SUCTION
PRESSURE

mbar

100 -4.8 -4.8 -0.5

HOT(APPROX)

wg -1.92 -1.92 -0.2

80 9.2-9.6 9.2-9.6 9.2-9.6

BURNER

9.0-9.4 9.0-9.4 9.0-9.4

%CO

2

100 9.2-9.6 9.2-9.6 9.2-9.6

9.0-9.4 9.0-9.4 9.0-9.4

m

3

/h

80 2.6 2.6 0.7

ft

3

/h 91.8 91.8 24.7

D.H.W Max. 8bar

working pressure (150lbf/in

2

)

IP classification

IP40

Internal Fuse rating

1) Type

2AF

2) Type

2AF

3) Type

3AT

TABLE 1

C.H. Max

D.H.W.Max MIN

CASING
DOOR ON

CASING
DOOR OFF

CASING
DOOR ON

CASING
DOOR OFF

m

3

/h

100 2.9 2.9 0.9

ft

3

/h 102.4 102.4 31.8

APPROX.
GAS RATE

SCHEMATIC LAYOUT OF BOILER

Advertising