5 preparation – Glow-worm EnergySaver 60 User Manual

Page 14

Advertising
background image

14

221836B

Diagram 5.1

Diagram 5.2

Diagram 5.3

SECURING
SCREW(4)

INNER
FITTING

M5x10mm

SELF TAPPER

Note: Casing securing screws
supplied in loose items pack.
Fit in order of numerical sequence.

No.10 x

3

/

4

INNER
CASE

6289

6290

6288

5 Preparation

BASE TRAY

WALL
TEMPLATE

TOP
CARTON
WRAP

BOILER MOUNTING

BRACKET

INSTRUCTIONS

TOP FITTING

5.1 Unpacking: diagram 5.1

Open top carton, remove top fitting, wall template, loose items
fittings pack and boiler mounting bracket.

Remove carton wrap and spacing pieces

Lift off white outer case front. Remove protective packing piece.

Remove the cover of the inner case, see diagram 5.3.

5.2 Rear and Side Flue Application

Having selected the location and flue application, with due
regard to the terminal position:

Take the template and temporarily position it on the wall see
diagram 5.4, making sure that the minimum clearances are
maintained.

For a rear flue, mark the position of the flue as diagram 5.4.

LOOSE ITEMS PACK

CONTROLS
FITTING

For a side flue, extend the centre line horizontally (taking into
account the required fall towards the boiler) left or right to the
corner of the adjacent surface where the flue is required to exit
to the outside. Alternatively, the increase in the centre height
over a distance “X” is given by H = 0.35X. Mark the position of
the centre of the flue as in diagram 5.4.