5 preparation – Glow-worm EnergySaver 60 User Manual

Page 15

Advertising
background image

15

221836B

Diagram 5.5

Diagram 5.4

WALL THICKNESS

115
DIAMETER

125
DIAMETER

135
DIAMETER

See template for centre line positions

75

300

680

REAR FLUE

0249M

0248M

"x"

SIDE FLUE

'H'=
0.035x

124mm

56.5mm MIN

115 Minimum hole
125 up to 300mm wall
135 up to 680mm wall

5 Preparation

5.3 Flue Hole Cutting

Having marked out the flue centre cut a hole for the flue see
diagram 5.5 for minimum core drill size for various wall
thicknesses.

This will allow for the 35mm per metre (2

o

) fall towards the boiler.

Note: If required, an optional Wall Liner Kit, part No.900862, is
available, complete with fixing instructions.

5.4 Wall Mounting Bracket

Reposition the template, making sure of dimensional alignment
with the flue centre lines

Mark the boiler securing screws and mounting plate position,
see diagram 5.6.

Drill holes and plug, fit the securing screws allowing sufficient
clearance to accept the keyhole fixing brackets and secure the
boiler mounting bracket to the wall.