Features, Troubleshooting – Go Power! GP-600 User Manual

Page 4

Advertising
background image

3. Features

3.1 Front view – GP-600

a)

AC outlet:
Outlet sockets available:

North America

b)

ON/ OFF switch:
Leave in the OFF position during installation.

c )

Power:
Lights green when GP-600 is on.

d)

Fault:
Lights red when when fault has occured.

Go Power! Modified Sine Wave Inverter

Owner’s Manual

Go Power! Modified Sine Wave Inverter

Owner’s Manual

9

4

a) AC outlet

c) Power

d) Fault

b) ON/ OFF switch

The power inverter will also shut down if the input voltage exceeds 15 V. This
protects the inverter against excessive input voltage. Although the power inverter
incorporates protection against over voltage, it may still be damaged if the input voltage
is allowed to exceed 20 V.

7.

Troubleshooting

7.1 Common problems

a) Buzz in audio systems

Some inexpensive stereo systems will emit a buzzing noise from their loud speakers
when operated from the power inverter. This is because the power supply in the
device does not adequately filter the modified sine wave produced by the power
inverter. The only solution is to use a sound system that incorporates a higher quality
power supply.

b) Television interference

Operation of the power inverter can interfere with television reception on some
channels. If this situation occurs, the following steps may help to alleviate the
problem.

• Do not operate high power loads with the power inverter while watching

television.

• Make sure that the antenna feeding your television provides an adequate

(“snow free”) signal and that you are using good quality cable between the
antenna and the television.

• Move the television as far away from the power inverter as possible.

• Keep the cables between the battery and the power inverter as short as

possible and twist them together with about 2 to 3 twists per foot. This
minimizes radiated interference from the cables.

7.2 Troubleshooting guide

Problem and Symptoms
Low AC output voltage
95-105 VAC.

No output voltage and LED
indicator is red.

No output voltage, LED
indicator is red.

No output voltage, no lights.

Possible Cause
Using standard voltmeter.
Overload.

Overload.

High input voltage.

Internal fuse open.

Solution
Use true RMS averaging
meter.

Reduce load.

Make sure that inverter is
connected to 12 V battery.
Check regulation of charging
system. Reduce load.

Make sure that inverter is
connected to 12 V battery.
Check regulation of charging
system.

Advertising