Failure modes, Typical depth of field by bar code element width, One razzberry tone – on power up – GoDEX GS220 User Manual

Page 10: Continuous razzberry tone with no leds, Three beeps – on power up

Advertising
background image

6

Failure Modes

One Razzberry Tone – On Power Up

This indicates the scanner has experienced a laser or flipper subsystem failure.

Return the unit for repair to an Authorized Service Center.

Continuous Razzberry Tone with no LEDs

If, upon power up, the scanner emits a continuous razzberry tone, then the

scanner has an experienced an electronic failure. Return the unit for repair to an

Authorized Service Center.

Three Beeps – On Power Up

If the scanner beeps three times on power up, then the non-volatile memory

(NovRAM) that holds the scanner configuration has failed. You must return the

unit for repair to an Authorized Service Center.

Typical Depth of Field by Bar Code Element Width

Bar Code Element

Width

Depth of Field

Start

(From Scanner Face)

End

(From Scanner Face)

0.13 mm

5.2 mil

76 mm (3")

127 mm (5")

0.19mm

7.5 mil

51 mm (2")

203 mm (8")

0.26 mm

10.4 mil

25 mm (1")

229 mm (9")

0.33 mm

13 mil

13 mm (0.5")

254 mm (10")

Advertising