Troubleshooting Guide

The following guide is for reference purposes only. Contact a customer service

representative to preserve the limited warranty terms.

Symptoms

Possible Causes

Solution

All Interfaces

The unit has no

LEDs, beep or laser.

No power is being

supplied to the

unit.

Check the transformer, the outlet

and power strip. Make sure the

cable is plugged into the unit.

No power is being

supplied to the unit

from host.

Some host systems cannot supply

enough current to power the

scanner. A power supply may be

needed.

At power up the

unit beeps two

times and

alternately flashes

the LEDs.

There is a ROM

failure.

A flash ROM upgrade is required.

At power up the unit

beeps three times.

There is a non-

volatile RAM

failure.

Contact a customer service

representative.

At power up there

is a continuous

razz tone.

There has been a

diagnostic failure.

At power up there

is a razz tone and

the green LED

flashes.

There is a VLD

failure.

At power up there

is a razz tone and

both LEDs flash.

There is a

scanning

mechanism

failure.

The unit scans,

communicates and

beeps twice.

The same symbol

timeout is set too

short.

Adjust the same symbol timeout

for a longer time.

The unit powers up,

but does not beep.

The beeper may

be disabled or no

tone has been

selected.

Enable beeper and select a tone.