Upon completing the gas line connection, a small amount of air will be in the lines.
When first lighting the pilot light, it will take a few minutes for the lines to purge
themselves of this air. Once the purging is complete, the pilot and burner will light and
operate as indicated in the instruction manual. Subsequent lighting of the appliance
will not require such purging.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERATURE AND SHOULD STAY
AWAY TO AvOID
BURNS OR CLOTHING
IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY
SUPERvISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.

IMPORTANT: TURN OFF GAS BEFORE SERvICING APPLIANCE. IT IS RECOMMENDED
THAT A COMPETENT SERvICE TECHNICIAN PERFORM THESE CHECKUPS AT
THE BEGINNING OF EACH HEATING SEASON.

WARNING: THE FLOW OF COMBUSTION AND vENTILATION AIR MUST NOT
BE OBSTRUCTED.

When lit for the first time, the appliance
will emit a slight odor for an hour or two.
This is due to paint and lubricants used
in the manufacturing process. The main
burner flame characteristics are steady,
not lifting or floating. Typically, the top
1/4 inch of the flame sensor should be
engulfed in the pilot flame. A periodic
check of these characteristics is
necessary (Figure 10).

MAINTENANCE INSTRUCTIONS

IMPORTANT: THE APPLIANCE AREA MUST BE KEPT CLEAR AND FREE FROM
COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.

Visually inspect pilot periodically. Brush or blow away any dust or linen accumulations.
If pilot orifice is plugged, disassembly may be required to remove any foreign material
from orifice or tubing.

Venting system should be periodically examined by a qualified service technician or
agency to ensure proper air flow.

10

Figure 10

OPERATING GUIDELINES

Flame

Sensor

Advertising