Error commands – Hall Research UHBX-SW3-WP User Manual
Page 19

17
© Copyright 2015. Hall Research, Inc.
All rights reserved.
UHBX-SW3-WP
Status Update
:
Command:
SU <cr> Stands for get full Status Update
Response:
PWn <cr> APn <cr> ISn <cr> AIn <cr> ODn <cr> SPn,m <cr> ARn
<cr> BNn <cr> CLn <cr> CTn <cr> ICn <cr> LRn <cr> OSn <cr>
TBn <cr> USn <cr> FWx.x <cr>
Factory Default:
Command:
FD <cr> Stands for Factory Default
Response:
FD <cr>
Firmware Version
:
Command:
FW <cr> Stands for Firmware Version
Response:
FWx.x <cr> UHBX-SW3-WP Firmware Version
Button
:
Command:
BLn,m <cr> Stands for Aux keypad Button LED
Response:
BLn,m <cr> Where n = 1 - 3 = PWR LED – MUTE LED
m = 0 - 1 = LED Off – LED On
Volume Up
:
Response:
UP <cr> Stands for Volume Up
Sent when user pushes the Volume Up button on Aux Kpd
Volume Down
:
Response:
DN <cr> Stands for Volume Down
Sent when user pushes the Volume Down button on Aux Kpd
Error Commands
ERR0 – UHBX-SW3-WP power is off.
ERR1 – Invalid command
ERR2 – The VGA scaler board is in low power mode
Notice
If n is not specified in any of the commands above, the
command becomes a query command instead of a set
command.
In response to a query command the system reports the
current status of that command.