INSPECTING BURNERS

Pilot Burner

Ignitor/Sensor

Figure 36 - Correct Pilot Flame Pattern

Sensing Rod

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame. Alterations
may have occurred during shipping and handling. The pilot is
located on the back right hand side of the burner.

The flame must envelope 1/4" of top of the ignitor/sensor and
grounding stem.

If your pilot assembly does not meet these requirements:

• Turn the adjustment screw marked PILOT clockwise to decrease

or counterclockwise to increase the flame to proper size (see
Figure 36). Do not remove the adjustment screw.

• see Troubleshooting, pages 19 and 20

OPERATING FIREPLACE

To Turn Off Gas To Appliance
Optional Remote Operation

INSPECTING BURNERS

Pilot Assembly

Figure 34 - Turning Equipment Shutoff Valve to the OFF Position

8.

Turn equipment shutoff valve counterclockwise

C-clockwise

to the ON position. Do not force.

9.

Replace front refractory brick access panel.

10. Fully close glass doors if installed.
11. Turn on all electric power to the appliance.
12. Turn the wall switch to the ON position.
13. Visually locate the pilot. The ignitor should begin to spark

and the main burner should ignite once flame appears at
pilot.
• If lighting the appliance for the first time each season, it

may take several attempts before the supply gas can reach
the pilot and main burners.

• If the appliance will not stay lit after several attempts,

follow the instructions To Turn Off Gas To Appliance,
below, and call your service technician or gas supplier.

Equipment
Shutoff Valve

Adjustment
Screw

TO TURN OFF GAS

TO APPLIANCE

1.

Turn off the wall switch.

2.

Turn off all electric power to the appliance if service is to
be performed.

3.

Fully open glass doors if installed.

4.

Remove front hearth brick and control access panel.

5.

Turn equipment shutoff valve clockwise

Clockwise

to OFF.

Do not force.

6.

Replace front refractory brick access panel.

7.

Fully close glass doors if installed.

Figure 35 - Pilot

Sensing Rod

Pilot Burner

Ignitor

OPTIONAL REMOTE

OPERATION

Note:

The WRC receiver and hand-held remote control kit

must be purchased separately (see Accessories, page 21). Follow
installation instructions on page 10.
1.

Turn equipment shutoff valve to ON position. You can now turn
the burner on and off with the hand-held remote control unit.

IMPORTANT:

Be sure to press the ON/OFF buttons on the

hand-held remote control unit for up to 3 seconds to assure
proper operation.

2.

Press the ON/OFF button to turn the burner on and off.

OPERATING FIREPLACE