Cleaning and maintenance, Inspecting burners, Continued – Desa VP324E User Manual

Page 17

Advertising
background image

108794-01D

17

17

For more information, visit www.desatech.com

For more information, visit www.desatech.com

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flames should
go up through the middle of logset. Flames should not "spill" to the
edges of the pan or sides of the logset.

Figure 37 shows a typical flame pattern. If burner flame pattern differs
from that described:

• turn appliance off (see To Turn Off Gas to Appliance, page 16)

• see Troubleshooting, pages 19 and 20

Figure 37 - Typical Flame Pattern

INSPECTING BURNERS

Burner Flame Pattern

CLEANING AND MAINTENANCE

Pilot and Burner

Logs

CLEANING AND
MAINTENANCE

WARNING: The logs can be hot. Handle only

when cool.

WARNING: Turn off gas and electrical power

before servicing appliance.

WARNING: Installation and repair should be done

by a qualified service person. The appliance should be
inspected before each use and at least annually by a
qualified service person. More frequent cleaning may
be required due to excessive lint from carpeting, bed-
ding material, pet hair, etc. It is imperative that the
control compartments, burners, and circulating air sys-
tem be kept clean.

PILOT AND BURNER

• Remove logs and ember material before cleaning burner and

replace when cleaning is complete.

• Burner and controls should be cleaned with compressed air to

remove dust, dirt, or lint.

• Use a vacuum cleaner or small, soft bristled brush to remove

excess dust, dirt, or lint.

LOGS

• If you remove logs for cleaning, refer to log placement informa-

tion on pages 12 and 13 to properly replace logs.

• Use a vacuum cleaner to remove any carbon buildup on logs.

• Replace log(s) if broken. See Replacement Parts, page 18.

• Replace ember material periodically as needed. See Replace-

ment Parts, page 18.

INSPECTING BURNERS

Continued

P325E(B) and VP325E(B) Models

P324E and VP324E Models

WARNING: Failure to keep the primary air

opening(s) of the burner(s) clean may result in soot-
ing and property damage.

Advertising