Konig Electronic Duo-pack wireless interconnectable smoke alarm User Manual

Page 7

Advertising
background image

ENGLISH

7

On ceilings

Install smoke alarms as close to the centre of

the ceiling as possible. If this is not possible,

install the smoke alarm at least 30 to 50 cm

from the wall.

(Due to dead air spaces)

Rooms with a gabled ceiling

Install the smoke alarm 90 cm from the

highest point.

(Due to dead air spaces)

ceiling mounting

minimum 30/50 cm

Minimum 90 cm

Note: when installing a smoke alarm in a hallway that is 7.5 metres or longer, we

recommended that you install a smoke alarm at the beginning and at the end of the

hallway.

Do not install a smoke alarm

‑ In a humid, dusty and smoky environment

‑ In rooms or areas where temperatures are below 4 °C or above 38 °C

‑ In the kitchen, bathroom or garage

‑ In drafty places

‑ Near a fan or air vent

‑ Above heating

Note: when installing a smoke alarm in a hallway that is 7.5 metres or longer, we

recommended that you install a smoke alarm at the beginning and at the end of the

hallway.