Service procedures – Desa CGB50N User Manual

Page 32

Advertising
background image

32

100351

SERVICE

PROCEDURES

Continued

Changing Burner Orifice

1. Shut off gas supply to

heater.

2. Remove lower front

access panel on heater.

3. Disconnect burner tube

from orifice holder (see
Figure 24).

4. Remove orifice holder

from burner (see Figure
24).

5. Use socket or open-end

wrench to remove the old
orifice from the orifice
holder.

6. Clean and replace orifice,

or replace with new
orifice.

7. Turn on gas to heater and

check for gas leaks. Apply
a mixture of liquid soap
and water to all joints.
Bubbles forming show a
leak. Correct all leaks at
once.

8. Replace lower front

access panel.

Figure 24 - Orifice Location (35,000 BTU/Hr Burner Shown)

Figure 25 - Orifice

Burner
Tube

Orifice
Holder

Orifice

Burner

Advertising
This manual is related to the following products: