Technical service, Service hints, Specifications – Desa CGB50N User Manual

Page 33

Advertising
background image

33

100351

TECHNICAL

SERVICE

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.

35,000 BTU/Hr

50,000 BTU/Hr

Model

Model

BTU

35,000

50,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

3.5" W.C.

3.5" W.C.

Inlet Gas Pressure

Maximum

7" W.C.

7" W.C.

Minimum

5" W.C.

5" W.C.

Dimensions, Inches

Heater (H x W x D)

25 x 27

1

/

4

x 16

28 x 32

1

/

2

x 16

Shipping Weight (pounds)

78

98

Flue Vent Size

4" dia.

4" dia.

Orifice Size

34 drill, ø .111

29 drill, ø .136

SPECIFICATIONS

Note:

These heaters are certified for elevations of 0-4500 feet above sea level. For

elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.

When gas pressure is too low

• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat

When gas quality is bad

• pilot will not stay lit
• burner will produce yellow flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.

SERVICE

HINTS

Advertising
This manual is related to the following products: