Preparing Manikin for Use:


Head:
Head is connected to torso with a long bolt at base of neck,
secured with a wing nut.

To remove:

1. Unfasten chest skin at shoulders.
2. Pull it back to expose chest cavity.
3. Lift hard chest plate to locate lungs and esophagus.
4. Lift esophagus, trachea and lungs out of way.
5. Unscrew and remove the wing nut and washer at

base of neck.

6. Head will now slip out of torso.

To attach, reverse procedure.

Lungs:
Lungs may be removed from bronchial tubes by unscrewing
them from connectors. To replace, reverse procedure.

Abdominal Thrust:
To remove abdominal thrust module, remove screws from
each side of manikin. Module will slide out. To replace,
reverse procedure.

Instructions for Use:


Airway Management:

• Spray inside of pharynx, both nostrils and all

intubation tubes with a liberal amount of Manikin
Lubricant or liquid soap.

• Recommended endotracheal tube size is 7.5 ID to 8.5

ID.

• The use of a stylet to assist when intubating is

recommended.

• Straight or curved laryngoscope blades, size 3 or 4

are recommended.


Manually Generated Carotid Pulse:
Locate red carotid pulse bulb on right side of manikin.
Squeeze bulb to generate desired pulse rate.


260-00001

Laerdal

6