Genitalia:

Both male and female genitalia have been provided for
urinary catheterization and enema training procedures.

Tube-like valves, with a screw cap on one end,
connect urethra and anus to corresponding
reservoirs. This cap must be connected to
genitalia openings. Soft vinyl end of connector
is attached to urinary and anal reservoirs with a white
clamp.
(Long valve connects urinary reservoir; short valve
connects anal reservoir
.) (Figure 2)


Fig. 2







Pelvic support pin must be removed
and replaced immediately when
assembling and disassembling genitalia.
(Figure 3)

Laerdal
Recommends


Pelvic support pin
must be replaced.

Failure to replace pin
will result in pelvic
spread.

If this occurs, the
genitalia module will
no longer fit properly.




Fig. 3






Pelvic Support
Pin

To assemble:

1. Screw both valves onto genitalia. (When attaching

valves, be sure alignment of genitalia, urinary reservoir
(belly plate) and colon reservoir are as illustrated in
Photo 1.)

2. Lift up on edge of belly plate.
3. Pull down upper portion of genital.
4. Insert into pelvic cavity.

5. Replace the pelvic support pin.
6. Press belly plate into position.

375-20001 Laerdal

6