Unpack:

MegaCode Kelly is packaged without the legs attached. Remove the upper
body and legs from the packaging and attach the legs to the torso.

To attach legs:

Step 1 Remove thigh injection pads (A), genitalia
module (B) and bladder reservoir assembly (C)
Step 2 Select and prepare hardware (Photo 1), pass spring
and small washer over bolt (Photo 2) Step 3 To install
pass bolt assembly through thigh, then pelvis opening
from outside inward (Photo 3), select large fender washer
and pass over bolt from inside manikin abdominal cavity.
Screw wing nut onto bolt (Photo 4) Step 4 Replace bladder
reservoir and genitalia module in pelvis, injection pad in thigh.
(See Step 1)
NOTE: Tighten wing nut as desired to simulate leg Range of
Motion.

SimPad Connection

1. Connect MegaCode Kelly

to SimPad (photo 1), cable located

on lower right side of manikin. You may have to use the cable adapter

2. Connect the clear tubing exiting the manikin’s right side to the back

(Advanced Version).

3. Attach blood pressure cuff to manikin’s left arm (Advanced Version).
4. Attach clear pneumatic tubing from blood pressure cuff (photo 2) to

corresponding clear pneumatic tubing exiting the manikins left (Advanced
Version).

Photo 1

Photo 2

Getting Started

Cricothyroid Membrane/ Neck Skin Collar:

1. Cut a two (2) inch strip of Cricothyroid Membrane Tape.
2. Adhere tape to edges of cricoid opening, covering opening with tape, to

create actual membrane.

3. Lay a Neck Skin Collar into molded track around neck area of manikin.
4. Attach collar using Velcro

®

strips.

Fig. 2

Laerdal Recommends

A tight seal will enhance actual feel and sound of penetrating

cricothyroid membrane, and facilitate full rise and fall of the chest

during bag valve mask ventilation.

Pupil Replacement
MegaCode Kelly is delivered with a set of pupils containing normal pupils
mounted in the head. A separate case contains 3 sets of plastic pupil
inserts (normal, constricted and dilated pupils) for use in simulating other
conditions.

To change the pupils in the airway head:

1. Open the eyelids wide, take care not to rip the faceskin.
2. Using the suction cup provided or the edge of you fingernail, remove the

pupil from the eye.

3. Replace with the pupil of choice, using the small suction cup tool

provided or press into place with finger.

In Use

Laerdal Recommends

• 7.5 Endotracheal tube

• # 4 LMA

• Large Adult or Trainer Combitube

• KING LT – # 4

Airway Management:

1. Spray inside of pharynx, nostrils and all intubation tubes with a liberal

amount of provided manikin lubricant or liquid soap. Sit the manikin
upright to allow lubricant to coat passages.

2. Perform further intubation procedures as per your local training

protocol.

NOTE: Should incorrect ventilation be performed, air will pass through esophagus,
causing distention of the abdomen.

Obstructed Airway (Manual Inflation of Tongue):

1. Locate

bulb at lower left side of torso labeled “tongue.”

2. Tighten air release knob.

3. Pump bulb several times to

tongue to desired size.

To

tongue, loosen air release knob.

Tension Pneumothorax Decompression
(Manual Inflation of Pneumothorax):

1. Locate

bulb which exits lower left side of manikin, labeled

“pneumo.”

2. Tighten air release knob so that as you pump the bulb, no air escapes.
3. Pump bulb several times to prepare three (3) sites for decompression.
4. Decompress the site, bilateral mid-clavicular or right side mid-axillary or

per your local training protocol.

When the site is “decompressed,” air can be heard/observed passing
through catheter.

MegaCode Kelly

3

Laerdal

Photo 4

A

C

B

Photo 1

Photo 2

Photo 3

B C

included in SimPad System.