2. Replacing Veins:
a. Lubricate inside of skin with liquid detergent.
b. Begin at top of arm and roll skin down and of arm and hand.
Thumb will detach with skin. (See Fig. 1)
c. Remove tubing from track in mandrel. Tack glue may
need to be cut away to allow removal.
d. Rinse and dry vein grooves well and swab with
alcohol. Be sure to remove any excess glue.
e. Place new veins along grooves, spot gluing as needed.
(See Fig. 2)
Fig. 2
f. Rinse inside of arm skin with soap and water.
g. Lather arm mandrel with liquid soap.
h. Slide arm skin over mandrel.
i. Work mandrel up into skin's fingers. (See Fig. 3)
j. Rinse off excess soap and dry.
Fig. 3
375-51001 6 Laerdal