LNC-2000 Receiving 0-5V Timing Retard Input from a Davis
Technologies TMS-Drag-MAP Series Traction Control Module
(Without the MAP Adapter)
A
B
C
LNC-2000
Red = MAP +5V
Black = MAP/Linear Ground
Purple = MAP/Linear Signal
F
= Linear Mode
.2 Volt = 0*
4.8 Volt = 15*
Max Retard
-Set the LNC-2000 to Linear Mode (”F” on
Timing Rate setting)
-Set the traction control module for the
desired timing retard ramp.
-Set the Max Retard setting on the LNC-2000.
-While the traction control module will
create the timing retard ramp, the LNC-2000
will still control the maximum timing retard.
The female MAP adapter connector must
either be modified or replaced because it
is keyed. The black and green wires also
need to be flipped so that the black wire
is pin A and the green wire is Pin B. There
are two solutions:
- LPE sells a keyless connector to replace
the stock connector (PN: L480320000).
- Remove the terminals from the stock
connector, drill out the keys in the
connector, and then reinstall the
terminals into the connector.
The TMS-Drag-MAP
Series Traction Control
Modules are property of
Davis Technologies
Page 27 of 31