LINK Systems System 1100 Tonnage Monitor User Manual

Page 114

Advertising
background image

ERROR CODES

___________________________________________________________________

Error No.

Message / Action

10-11

The Data window 2 high setpoint of the channel
indicated by the error code is set to a value less
than the low setpoint.

1)

Adjust the high or low setpoint so that the high
setpoint is greater than the low setpoint.

096

Data window 3, channel 1 high setpoint too high.

097

Data window 3, channel 2 high setpoint too high.

098

Data window 3, channel 3 high setpoint too high.

099

Data window 3, channel 4 high setpoint too high.

The Data window 3 high setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.

1)

Check the MACH RATING setting in the Config menu
for correctness.

2)

Adjust the indicated setpoint to a setting less
than 125% of the channel rating.

100

Data window 3, channel 1 low setpoint too high.

101

Data window 3, channel 2 low setpoint too high.

102

Data window 3, channel 3 low setpoint too high.

103

Data window 3, channel 4 low setpoint too high.

The Data window 3 low setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.

1)

Check the MACH RATING setting in the Config menu
for correctness.

2)

Adjust the indicated setpoint to a setting less
than 125% of the channel rating.

104

Data window 3, channel 1 reverse setpoint too high.

105

Data window 3, channel 2 reverse setpoint too high.

106

Data window 3, channel 3 reverse setpoint too high.