UNBALANCED LOADS AND SCALE FACTOR

___________________________________________________________________

8-3

ORIGINAL MACHINE RATING

N1

N1

C' = ------------------------- * C

NEW MACHINE RATING

ORIGINAL MACHINE RATING

N2

N2

C' = ------------------------- * C

NEW MACHINE RATING

ORIGINAL MACHINE RATING

N3

N3

C' = ------------------------- * C

NEW MACHINE RATING

and

ORIGINAL MACHINE RATING

N4

N4

C' = ------------------------- * C

NEW MACHINE RATING

N1

N2

N3

N4

where C' , C' , C' , C' , are the new calibration numbers to which

N1

N2

channels 1 through 4 should be adjusted, respectively. C , C ,

N3

N4

C , C , are the original calibration numbers for channels 1 through
4, which were determined by the procedures followed in the Section
6 of this manual.

The following examples illustrate how the System 1100 Tonnage
Monitors on the machines of Examples 1 and 2 of this section can be
set up to permit more tonnage on each channel while retaining
calibration.

Example 3. Following the instructions in the Section 6 of this
manual for the two channel System 1100 unit on the machine of
Example 1 resulted in a machine rating number of 100.0 tons being
programmed into the unit. The calibration numbers were found to be
144 for channel 1 and 148 for channel 2. It is desired to shift
the machine rating alarms on each channel from 62.5 tons (125% of
50 tons for each side) to 70 tons for each channel. To do this,
calculate the new machine rating number (scale factor). The
required number is:

70 tons

MACHINE RATING NUMBER = --------- = 112 tons