Control box settings – Mighty Mule MM600ET-PRO User Manual

Page 31

Advertising
background image

Turn the “STALL FORCE” arrow in the center of the potentiom-
eter with small flat head screwdriver. Adjust the sensitivity from the
MINIMUM position up to the point where the gate operates without
obstructing from its own weight or the wind conditions in your area.

Turn the “AUTO CLOSE TIME” arrow in the center of the potentiom-

eter with small flat head screwdriver to determine how long the gate

will remain open before it automatically closes. The limits are OFF

and 3 - 120 seconds. The factory setting is OFF.

1 2 3 4

ON

STATUS

LEARN RMT

LEARN

MAST LIMIT

OFF

SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF

ON
ON
PUSH
SIMULT.
ON
ON

120 MIN

MAX

AUTO CLOSE TIME

STALL FORCE

1

BATT+

1 2 3 4

OFF

SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF

120 MIN

AUTO CLOSE TIME

STALL FORCE

2

IMPORTANT: For safety reasons the obstructions setting or Stall Force on the Mighty Mule®

control board comes from the factory set at MIN (minimum). In many installations this setting

will need to be adjusted to overcome the weight and size of the gates.

ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING YOUR

AUTOMATIC GATE OPENER

28

Control Box Settings

Setting Obstruction Stall Force & Auto Close Time

Setting Personal Transmitter Code

Remove back cover of the opener remote.

Flip opener remote over. Use small screwdriver to move switch-
es to random positions. If you have more than one transmitter,
now is a good time to set them all with the same code.

1

1 2 3 4 5 6 7 8 9

2

All GTO transmitters are set to a standard code at the factory and are ready to operate your gate opener.
For your safety and security, however, we

strongly recommend that you replace the factory setting with your own personal code.

Follow the directions below: