INSTALLATION ITEMS

Before installing fireplace, make sure you have

the items listed below.

• external regulator (supplied by installer, for

propane/LP units only)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection*

• ground joint union

• sediment trap

• tee joint

• pipe wrench

* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 40.
Note:

If desired, purchase a four-sided perimeter

trim kit for built-in installations. See Accessories,

page 40.

FIRePLACe CLeARANCeS

WARNING: Maintain the

minimum clearances shown

in Figure 6. If you can, provide

greater clearances from floor,

ceiling and joining wall.

If your fireplace is to be used with an optional

mantel, the installation instructions included with

your mantel shows an CSA approved method of

attaching the fireplace/mantel system to a wall.

IMPORTANT:

Only use optional cabinet or

corner mantels specified in this manual. Purchase

the optional mantel from your dealer (see Acces-

sories, page 40).

If your fireplace is to be recessed into the wall,

see Built-In Fireplace Installation on page 11 to

secure your fireplace into the wall.

CAUTION: If you install the

fireplace in a home garage

• fireplace pilot and burner must

be at least 18 inches above

floor.

• locate fireplace where moving

vehicle will not hit it.

iNsTallaTioN

Continued

For convenience and efficiency, install fireplace

• where there is easy access for operation, inspec-

tion and service

• in coldest part of room

An optional blower kit is available from your

dealer. See Accessories, page 40. If planning to use

blower, follow instructions provided with blower

for power source.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling

A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 6.

Example: The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 6).

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 36 inches.

C. For mantel clearances, see Figure 10 on

page 12.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

Right Sides

and Rear

36"

6"

0"

Figure 6 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

*

Example