background image

www.desatech.com

116526-01B

20

iNsTallaTioN

Continued

4. Gently remove the cover of the thermostat

from the base. Grasp the sides of the cover

firmly and pull to separate from the base.

5. Feed the electrical wires through the rectangular

slots on each side of the base (see Figure 31).

WARNING: Do not con-

nect the thermostat to a power

source. electrical shock and/or

a fire hazard will occur.

6. Connect one bare wire end to each terminal

(“W” and “R”) of the thermostat base (see

Figure 32).

Figure 31 - Back View of Thermostat Base

Feed wires through
rectangular slots

W

R

Figure 32 - Thermostat Base Terminals

“W” and “R”

Terminal “W”

Terminal “R”

Figure 30 - Connecting Wire Terminals

To Wall
Thermostat
or Switch

To Wall
Thermostat
or Switch

Control Valve

OPTIONAL WALL SWITCH - GWMS2
(Remote-Ready Models Only)

WARNING: Read and fol-

low installation instructions.

Installation should be done by

a qualified installer familiar with

low-voltage wiring procedures.

WARNING: Do not connect

this switch to any electrical

source! electrical shock and/or

fire hazard will occur.

1. Remove jumper wire from control valve (see

Figure 26, page 19).

2. Connect one terminal of 25 ft. wire to the

“TH” terminal on the control valve. Connect

the other terminal to the “THTP” terminal on

the control valve. See Figure 30.

3. Route the 25 ft. wire to a convenient location

to mount your wall switch (no outside walls).

WARNING: Do not connect

the switch to a power source.

electrical shock and/or fire haz-

ard will occur.

IMPORTANT:

The wire may be shortened but

must not be lengthened.

4. Connect one bare wire end to each of the

terminals of the provided wall switch.

5. Install the wall switch and cover in the wall.

7. Install the base onto the wall with the pro-

vided screws.

8. Move the temperature adjustment back and forth

to insure the bimetal is free from restrictions.

9. Replace the cover onto the base. (Upon in-

stallation, the thermostat must be allowed to

stabilize at room temperature for a minimum

of 30 minutes for proper operation).

10. Set the temperature adjustment to the desired

setting. This thermostat has been electroni-

cally calibrated at the factory. No adjustment

or leveling is necessary.

Advertising