Installation – Desa VDCFTNB User Manual

Page 12

Advertising
background image

www.desatech.com

116526-01B

12

15"

18"

21"

23"

2

1

/

2

"

6"

8"

10"

Note:
All vertical
measurements
are from top of
fireplace
opening to
bottom of
mantel shelf. All
measurements
are in inches.

10. If using optional trim kit, install the trim after

final finishing and/or painting of wall. See

instructions included with trim accessory for

attaching trim.

IMPORTANT:

When finishing your firebox,

combustible materials such as wall board, gypsum

board, sheet rock, drywall, plywood, etc. may be

butted up next to the sides and top edge of the fire-

box. Combustible materials should never overlap

the firebox front facing.

WARNING: Do not allow any

combustible materials to overlap

the firebox front facing.

IMPORTANT:

Noncombustible materials such as

brick, tile, etc. may overlap the front facing, but

should never cover any necessary openings like

louvered slots.

WARNING: Do not allow

noncombustible materials to

cover any necessary openings

like louvered slots.

WARNING: Never modify or

cover the louvered slots on the

front of the firebox.

WARNING: Use only noncom-

bustible mortar or adhesives when

overlapping the front facing with

noncombustible facing material.

Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must

meet minimum clearance between mantel shelf and

top of fireplace opening.

NOTICE: Surface temperatures

of adjacent walls and mantels be-

come hot during operation. Walls

and mantels above the firebox

may become hot to the touch.

If installed properly, these tem-

peratures meet the requirement

of the national product standard.

Follow all minimum clearances

shown in this manual.

iNsTallaTioN

Continued

Figure 10 - Minimum Mantel Clearances

for Built-In Installation

Mantel Shelf

Side of Firebox

Figure 11 - Removing Top Louver and

Opening Bottom Louver

O
F

F


P

ILO

T

O

N

H

I



L

O

Top
Louver

Bottom Louver

NOTICE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• raise the mantel to an accept-

able height

• remove the mantel

OPTIONAL MANTeL INSTALLATION

Note:

Refer to instructions provided with the mantel

for assembly instructions. Refer to the following

instructions for system installation. Refer to instruc-

tions on page 4 for hood assembly. Blower accessory

should be installed if it is being used (see Installing

Optional Blower Accessory GA3450TA, page 13).

1. Unscrew four screws that attach top louver to

fireplace. Remove louver from fireplace and

set aside (see Figure 11).

2. Place base assembly next to wall at installation

location.

3. Place fireplace on wood base (see Figure 12).

Advertising