INSTALLING LOG SET AND SCREEN

1. Remove log packaging material and discard

packaging. Gently place log over burner (see

Figure 33). Do not allow log to contact flame.

If flame contacts log, soot will be created.

2. Reattach screen by placing the notches in the

screen frame over the shoulder screws and

pushing down.

iNsTallaTioN

Continued

Log

Shoulder
Screw

Screen

Figure 33 - Installing Log and Screen

opERaTiNG FiREplaCE

THERmosTaT-CoNTRollED

moDEls

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

LIGHTING

INSTRUCTIONS

WARNING: You must operate

this fireplace with the screen

in place. Make sure fireplace

screen is installed before run-

ning fireplace.

NOTICe: During initial opera-

tion of new fireplace, burning

logs will give off a paper-burn-

ing smell. Open window to vent

smell. Operate fireplace on HI

position to burn off odor. This

will only last a few hours.

1. STOP! Read the safety information starting

in column 1.

2. Make sure equipment shutoff valve is

fully open.

3. Turn control knob clockwise

to the

OFF position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information in column 1. If you don’t

smell gas, go to the next step.

5. Turn control knob counterclockwise

to the PILOT position. Press in control knob

for five (5) seconds (see Figure 34, page 22).

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas

supplier’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the

knob will not push in or turn by hand, don’t

try to repair it, call a qualified service tech-

nician or gas supplier. Force or attempted

repair may result in a fire or explosion.

D. Do not use this appliance if any part has been

under water. Immediately call a qualified

service technician to inspect the appliance and

to replace any part of the control system and

any gas control which has been under water.