Installation – Desa Compact 150 Watt Motion Sensing Halogen 5511 User Manual

Page 2

Advertising
background image

2

598-1310-00

❒ Drill out the holes if needed

to mount the backplate to the
junction box.

INSTALLATION

For easy installation, select an existing light with a wall
switch for replacement.

For best performance, locate the fi xture about 8 ft. (2.4 m)
above the ground.

CAUTION: The sensor must be mounted below the
lamp housing for wall installations.

❒ Remove the existing light fi xture.
❒ Strip about 5/8" insulation from the existing junction

box wiring.

❒ Route the Light Control’s wires through the large

hole in the gasket.

❒ Twist the junction box wires and fi xture wires together

as shown. Secure with wire connectors.

❒ Align the Light Control cover plate and cover plate

gasket and the junction box. Insert and tighten the
mounting screws.

❒ If not installed on a weatherproof box or if an adaptor

plate is used, caulk the wall plate and mounting
surface
with silicone weather sealant.

M

OUNT

THE

L

IGHT

C

ONTROL

Cover Plate

Gasket

The halogen light must be
mounted horizontally (+/- 4°).

RIGHT

WRONG

B

ULB

I

NSTALLATION

AND

R

ELAMPING

❒ When

relamping,

turn power off and let the fi xture

cool.

❒ Remove the screw that holds the glass cover shut.

Remove the old bulb by pushing the bulb towards
the right until the left side of the bulb is clear of the
left socket.

CAUTION to avoid fi re or burn hazards:

• Allow fi xture to cool before touching. The bulb

and fi xture operate at high temperatures.

• Keep fi xture at least 2" (5 cm) from combustible

materials. Do not aim at objects closer than 3 feet
(1 m).

• Re-lamp with type T 150W (or less) halogen 120

VAC lamp only.

For under eave installation, the sensor head must
be rotated
as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.

Black to Black

White to White

Rotate the sensor head to-
wards the clamp screw joint.

Then rotate the sensor
head counterclockwise
180° so the controls face
down.

Controls

Junction box ground wire to
green ground wire on fi xture.

W

IRE

THE

L

IGHT

C

ONTROL

If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.

Clamp Screw

Controls

❒ To insert the new bulb, push the bulb into the right

socket so the bulb fi ts completely into the left
socket.

❒ Check that the bulb is seated properly.
❒ Close the glass cover. Replace screw.

WARNING: Turn power off at circuit breaker

or fuse.

Advertising