paragraph 10, then inserting the leak detector probe into the blower

resistor block or condensate drain hold if no water is present, or into

the closest opening in the heating/ventilation/air conditioning case

to the evaporator, such as the heater duct or a vent duct. If the

detector alarms, a leak apparently has been found.

10. The accumulation time shall be 10 minutes.

11. Following any service to the refrigerant system of the vehicle, and

any other service which disturbs the refrigerant system, a leak test

of the repair and of the service ports of the refrigerant system shall

be done.

BATTERY INSTALLATION AND
REPLACEMENT

Ÿ Turn the power off.
Ÿ Remove the battery cover from the back of the instrument by

pressing down while simultaneously sliding the cover back. Be

careful not to lose the extra sensor stored in the battery

compartment.

Ÿ Insert 2 size ‘AA’ alkaline batteries.
Ÿ Slide battery cover back into place.

English

5

SENSOR

A STARTEK sensor will last between 25 and 30 hours of continuous use.

A failed or failing sensor will be indicated in one of the following ways:

1.

Unstable or erratic operation of the unit and many false alarms,

even in pure air.

2.

A continuous “siren” sound.

SENSOR REPLACEMENT

In either case, replacement of the sensor is necessary:


Ÿ Turn the power off.
Ÿ Locate the replacement sensor in the battery compartment.
Ÿ Unscrew (turn counter clockwise) the old sensor from the end of the

probe.

Ÿ Screw (turn clockwise) the new sensor into place.

MAINTENANCE

The STARTEK should provide years of service with little maintenance

aside from changing batteries and sensors. The case may be cleaned

with a shop towel moistened with water and a mild detergent. Do not

use solvent of any kind.