Continuous controller assignments - version 1.00 – Rocktron RepliTone MP User Manual

Page 14

Advertising
background image

14

Continuous Controller Assignments - Version 1.00

The Controller Assignments for some of the RepliTone MP's parameters such as volume, delay, reverb and
effects can be adjusted for "real-time" control by continuous controller assignments or midi and/or expresssion
pedal.

Here are the RepliTone assignments:

Controller

Lower

Upper

Function

Change Number

Value

Value

Tap Delay

015

0

127

EFX Rate

016

0

127

Volume

017

0

127

Delay Mute

018

0

127

Reverb Mute

019

0

127

EFX Mute

020

0

127

Wah In/Out

021

0

127

EFX Adjust 1

022

0

127

EFX Adjust 2

023

0

127

Rotary On/Off

024

0

127

EFX1 and EFX2 will control any adjust parameters associated with the algorithm recalled.
For example - Wah Wah = [On/Off = cc#21 Value - 0 = off 127=on] Wah Frequency = CC#22 Value
0----127

Here is a breakdown of the controller numbers per effect for quick reference:

Effect Parameter

On/Off

Effect Adjust

Delay Tap

-

15

Rate Tap

-

16

Volume

-

17

Delay Mute

18

-

Reverb Mute

19

-

Chorus Depth

20

22

Chorus Level

20

23

Flanger Depth

20

22

Flanger Res (Resonance)

20

23

Delay Regen (Regeneration)

18

22

Delay Pan

18

23

Detune Pitch

20

22

Detune Level

20

23

Bypass

-

-

HUSH

-

22

Compressor

-

22

Wah (In/Out)

21

22

Rotary

20

24

Phaser (Depth)

20

22

Tremolo 1 (Depth)

20

22

Tremolo 2 (Depth)

20

22

Advertising