Natural gas heater cgn10a and cgn6 – Desa CGN10A User Manual

Page 10

Advertising
background image

10

101870

NATURAL GAS HEATER

CGN10A AND CGN6

TO TURN OFF GAS
TO APPLIANCE

Shutting Off Heater

1.

Turn control knob clockwise
to the PILOT position.

2.

Press in control knob and turn clock-
wise

to the OFF position.

Shutting Off Burner Only (pilot
stays lit)

1.

Turn control knob clockwise
to the PILOT position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas, STOP!
Follow “B” in the safety information
at the top of column 3, page 9. If you
don’t smell gas, go to the next step.

5.

Press in control knob and turn coun-
terclockwise

to the PILOT

position. Keep control knob pressed
in for five (5) seconds (see Figure 15).

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. The pilot can
be seen through the glass panel. If
needed, keep pressing ignitor button
until pilot lights.

Note:

If pilot does not stay lit, refer

to Troubleshooting, pages 12 through
14. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot
with match. To light pilot with match,
see Manual Lighting Procedure
.

Thermocouple

Pilot Burner

Ignitor Electrode

Figure 16 - Pilot

CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

LIGHTING
INSTRUCTIONS

1.

STOP! Read the safety information
page 9, column 3.

2.

Make sure manual shutoff valve is
fully open.

3.

Turn control knob clockwise

to the OFF position.

OFF

HIGH

PILOT

LOW

IGNITOR

Ignitor Button

Control Knob

Figure 15 - Control Knob In The OFF
Position

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7.

8.

Turn control knob counterclockwise

to the HIGH position. The

main burner should light. Set control
knob to any heat level between HIGH
and LOW. To turn control knob from
HIGH to a lower setting, press in the
control knob and turn counterclock-
wise

.

Note:

Both HIGH and LOW are

locked positions. You must press in
control knob before turning it from
these positions.

1.

Remove front panel (see Figure 10,
page 7).

2.

Follow steps 1 through 5 under Light-
ing Instructions
.

3.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

4.

Keep control knob pressed in for 30
seconds after pilot is lit. After 30 sec-
onds, release control knob.

5.

Replace front panel.

MANUAL LIGHTING
PROCEDURE

Advertising
This manual is related to the following products: