User’s Manual

2

Notice to Users

female receptacle of the cord set must meet IEC-60320 requirements
and may look like (Figure A1 below):

For the United States and Canada

In the United States and Canada, the male plug is a NEMA5-15 style
(Figure A2), UL Listed, and CSA Labeled. For units that are mounted
on a desk or table, type SVT or SJT cord sets may be used. For units
that sit on the floor, only SJT type cord sets may be used. The cord
set must be selected according to the current rating for your unit.
Please consult the table below for the selection criteria for power
cords used in the United States and Canada.

Code Type Size of Conductors in Cord

Maximum Current Rating

of Unit

SJT


18 AWG
16 AWG
14 AWG

10 Amps
12 Amps
12 Amps

SVT

18 AWG
17 AWG

10 Amps
12 Amps

For European Countries

In Europe, you must use a cord set which is appropriate for the
receptacles in your country. The cord set is HAR-certified, and
includes a special mark that appears on the outer sheath or on the
insulation of one of the inner conductors.

For The United Kingdom

For your safety please read the following text carefully. If the fitted
molded plug is unsuitable for the socket outlet, then the plug should
be cut off and disposed of safely. There is a danger of severe
electrical shock if the cut off plug is inserted into an appropriate
socket. If a new plug is to be fitted, please observe the wiring code as
shown below. Please consult a qualified electrician if you have any
questions.