Troubleshooting – Star Headlight & Lantern 5400 Series 46" LED Packages User Manual

Page 12

Advertising
background image

-9-

Symptom

Possible solutions

Flash Pattern is not changing

Pattern select wire must be pulled to +12VDC to
change pattern.

Unit stuck in high power

High/Low wire must be grounded to activate
low power mode.

Bar is not synchronizing with
other product

-Check to ensure all desired lights to be
synchronized have the capability of being
synchronized.

-Check to ensure synchronization wire is
connected to all units that are desired to be
synchronized.

-Check to ensure all lights to be synchronized
are set to same Pattern Type.

-Ensure that the entire system that is desired to
be synchronized is powered up at the same
time via the same switch.

-Ensure that the total amount of synchronizable
products in the system does not exceed 6 lights.

One single LED is out.

The entire flasher board will need to be
replaced.

One complete half of the bar is
out.

-Check wiring to the flasher board that is
experiencing the problem.

-The entire LED board on that side may need to
be replaced.

If the bar is experiencing erratic
flashing or side to side
synchronizing within the bar is
not working.

-Ensure both sides are set to the same Pattern
Type

.

-Ensure synchronization wire is connected
between both flasher boards internally.

-Ensure both flasher circuits in the bar are
powered from the same power switch.

Troubleshooting

Advertising