1. To begin the programming sequence, power up the light so that it is flashing.

2. To change the flash pattern, press and release the Pattern Select Button

(cig plug models only) or briefly touch and release the Red w/Green Stripe
wire to +12-24VDC (hard-wired versions only). Repeat this to scroll
through the patterns listed below. The cycle repeats after the last pattern.

There are several patterns that you can
“jump” to via programming shortcuts. Touch
and hold the Red w/Green Stripe Wire to
+12/24VDC (or hold the Pattern Select
Button) for the length of time that corresponds
to the pattern you would like to jump to.

3. Once you find the pattern you wish to display, tape off the Red w/Green wire (hard-wire

only) and deactivate the light. This will store the selected pattern.

Hold For

Unit Blinks

Shortcut to

3 seconds

1 time

Pattern 1

6 seconds

2 times

Pattern 6

9 seconds

3 times

Pattern 13

12 seconds

4 times

Pattern 16

Flash

Pattern #

Pattern

Type

Pattern List

CPS

1

K

Alternating Flicker †

1.0

2

L

Alternating Fast Doubleflash

3.3

3

M

Alternating Tripleflash

2.5

4

N

Alternating PSU Flicker

0.7

5

O

Alternating PSU Random

0.6

6

F

Alternating Quadflash ††

1.0

7

G

Alternating Quadflash w/Post-Pop

1.0

8

H

Alternating Singleflash

1.0

9

I

Alternating Doubleflash

1.0

10

J

Alternating Variable

0.3

11

C

Post Pop

1.4

12

E

Random

0.4

13

P

Alternating Quintflash †††

1.2

14

R

Alt. Fast Doubleflash, Alt. Flicker

N/A

15

S

Alt. Quad, Alt. Flicker, Alt. Double, Flicker

N/A

16

G

Sim. Quad w/Post Pop (Phase 1) ††††

1.0

17

G

Sim. Quad w/Post Pop (Phase 2)

1.0

18

U

Alt. Triple, Alt. Non-Synch Double, Alt. Quint, Flicker

N/A

19

V

Steady burn one side, Other side Single Flash

1.0

20

NONE

Cycle All

N/A

† = Programming Shortcuts 1, 2, 3, and 4 (see table above)

Black - (Ground) Connect to the negative side of the battery.

Purple - (Optional - High/Low) Used to switch the light between High and Low power.

• Leave disconnected for High Power only (cover with wirenut or tape).

• Connect to Ground for Low Power only.

• Connect to Ground through a switch for High/Low switching option.

White - (Synchronization) Used to synchronize two lights together. If you are only installing

one unit, cut the White wire short and tape the end. If you will be synchronizing
two or more approved synchronizable lights, leave the white wire disconnected for
now
. Connect the white wires from both units together ONLY AFTER
PROGRAMMING
them for the same pattern (see Pattern Programming).

Red - (Power) Connect to +12-24 VDC through your switch. Be sure to use a 10 amp

fuse when connecting the switch to the positive side of the power supply.

Red w/Green - (Pattern Select) Touch and release to +12-24 VDC to change patterns.

Hard Wire Instructions

(Perm Mount Models)

Pattern Programming

Advertising