Installing the receiving frame – StorCase Technology DE100i-SWCU2 User Manual

Page 16

Advertising
background image

Installation

9

DE100i-SWCU2 User's Guide - Rev. B02

StorCase Technology, Inc.

Figure 7: Receiving Frame Motherboard Option Pins

Installing the Receiving Frame

NOTES:

DE100i-SWCU2 requires LVD chassis and cabling.

DE100i-SWCU2 supports implementations with a maximum of 9 drives.

The drive should be installed into the carrier before installing the receiving frame into the

mounting bay of a computer or expansion chassis. A #2 Phillips screwdriver will be required

for installation.

1.

Turn OFF power to the computer.

2.

Open the computer system according to the manufacturer’s instructions. If

necessary, temporarily remove any expansion boards that may make installation

difficult.

3.

To select the DE100i-SWCU2 unit ID remotely through the computer system or

external expansion chassis, the appropriate cable from the system must be

connected to the ID Select Pins 1-8 on the rear of the receiving frame as shown

in Figure 7.