Lun mapping – StorCase Technology InfoStation 16-Bay 3U SCSI/SATA User Manual
Page 63

50
RAID Controller Configuration
StorCase Technology, Inc.
InfoStation 16-Bay RAID User's Guide - Rev. F00
LUN Mapping
1.
After the array and partitions have been created, each partition needs to be as-
signed a LUN and mapped to the appropriate SCSI Channel.
2.
<TAB> to the Menu (left) side of the screen and press <ENTER>.
3.
Enter password (default password = 00000000).
4.
Select SCSI Params and press <ENTER>.
a.
Select the SCSI channel your host server is connected to (Primary or Sec-
ondary SCSI) and press <ENTER>.
b.
Select LUN MAP and press <ENTER>.
c.
Starting with LUN 0, assign one LUN number to each partition (slice).
Select LUN number and press <ENTER>.
d.
After selecting LUN number, select the array the partition is in and press
<ENTER>.
e.
Select the partition (slice) you would like to assign this LUN number to and
press <ENTER> (Figure 22).
Slices always start with “00” and increase sequentially according to the
number of partitions that have been created.