background image

50

RAID Controller Configuration

StorCase Technology, Inc.

InfoStation 16-Bay RAID User's Guide - Rev. F00

LUN Mapping

1.

After the array and partitions have been created, each partition needs to be as-
signed a LUN and mapped to the appropriate SCSI Channel.

2.

<TAB> to the Menu (left) side of the screen and press <ENTER>.

3.

Enter password (default password = 00000000).

4.

Select SCSI Params and press <ENTER>.

a.

Select the SCSI channel your host server is connected to (Primary or Sec-
ondary SCSI) and press <ENTER>.

b.

Select LUN MAP and press <ENTER>.

c.

Starting with LUN 0, assign one LUN number to each partition (slice).

Select LUN number and press <ENTER>.

d.

After selecting LUN number, select the array the partition is in and press
<ENTER>.

e.

Select the partition (slice) you would like to assign this LUN number to and
press <ENTER> (Figure 22).

Slices always start with “00” and increase sequentially according to the
number of partitions that have been created.