ii.

Wiring Fault

When connected to an incorrectly wired branch circuit outlet, in addition to the
illumination of the Red LED, the LCD Event Monitor will display the following
information:










iii.

Abnormal Voltage

When the magnitude of the branch circuit outlet voltage is not acceptable*,
the Filter will disconnect power to its outlets and display the following
information on the LCD Event Monitor (*above the over-voltage shutdown
threshold or below the under-voltage shutdown threshold; refer to Section IV:
Diagnostic Software for more information):











Wiring Fault Condition

Display

Example Display

Line (Hot) / Neutral
Reversed
(120V products only)

rP (Reverse
Polarity)

Missing Ground

gnd (no Ground)

Voltage Condition

Display

Example Display

Over-Voltage

OFF + ▲ + Voltage

Under-Voltage

OFF + ▼ + Voltage