Propane/lp safety, Warning: for outdoor use only, Safety information – Desa SPC-21PHTSA User Manual

Page 4

Advertising
background image

www.desatech.com

114082-01C

4

16. Use only soapy water (1 part liquid dishwash-

ing detergent to 3 parts water) to conduct

leak tests whenever a propane cylinder is

connected. Bubbles indicate a leak.

17. Do not adjust gas regulator. If you are unsure

of your appliances gas type or pressure, call

a qualified service person.

18. Place the control knob on "OFF" position

when heater is not in use.

19. Always disconnect the gas supply after the

heater is turned "OFF".

20. Do not move, handle or service while hot or

burning.

21. Allow 45 minutes to cool down after use

before attempting to move heater.

22. Do not operate this appliance in windy condi-

tions. Maximum allowable wind speed is 10 mph

(16 Km/h).

23. Do not operate this appliance in temperature

conditions below 40° F (5° C).

24. Keep heater away from areas where flammable

liquids, vapors or solids are stored or used.

25. If operated in salt air environments, the

unit will require more frequent cleaning;

otherwise, the longevity of the unit will

deteriorate rapidly. Use warm soapy water to

clean the unit.

26. Items or material, when stored under the

heater, will be subjected to radiant heat and

could be seriously damaged.

27. Use only in accordance with local codes, or in

the absence of local codes, with the National

Fuel Gas Code ANSI Z223.1.

Any guard or other protective device
removed for servicing must be re-
placed prior to operating the heater.

Surface temperatures become very
hot when operating heater. Children
and adults should stay away to avoid
burns or clothing ignition.

Young children should be carefully
supervised when they are in the area
of the heater.

Clothing or other flammable mate-
rials should not be hung from the
heater, or placed on or near heater.

Installation and repair should be
done by a qualified service person.
The heater should be inspected
before use and at least annually by
a qualified service person. More
frequent cleanings may be required
as necessary. It is imperative that
control compartments, burners and
circulating air passageways of the
heater be kept clean.

CAUTION: The gas pressure

regulator provided with this ap-

pliance must be used. This regu-

lator is set for an output pressure

of 11" W.C. (2.74 kPa).

PROPANE/LP SAFETY

WARNING: For outdoor

use only.

ASPHYXIATION HAZARD

• Do not use this heater for heating human

living quarters.

• Do not use in unventilated areas.
• The flow of combustion and ventilation

air must not be obstructed.

• Proper ventilation air must be provided

to support the combustion air require-
ments of the heater being used.

• Refer to the Specifications, page 2, heater

data plate or contact DESA Heating Prod-
ucts to determine combustion air ventila-
tion requirements of the heater.

• Lack of proper ventilation air will lead

to improper combustion.

• Improper combustion can lead to carbon

monoxide poisoning leading to serious
injury or death. Symptom of carbon mon-
oxide poisoning can include headaches
dizziness and difficulty in breathing.

SAFETY INFORMATION

Continued

Advertising