Troubleshooting – Desa SPC-21PHTSA User Manual

Page 9

Advertising
background image

www.desatech.com

114082-01C

9

TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note:

All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Ignitor electrode positioned

wrong

2. Ignitor electrode broken

3. Ignitor electrode not con-

nected to ignitor cable

4. Ignitor cable pinched or wet

5. Broken ignitor cable

6. Bad piezo ignitor

1. Control knob not fully pressed in

2. Control knob not pressed in

long enough

3. Safety interlock system has

been triggered

4. Thermocouple connection

loose at control valve

5. Pilot flame not touching

thermocouple, which allows

thermocouple to cool, caus-

ing pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

6. Thermocouple damaged

7. Control valve damaged

1. Burner orifice is clogged

2. Inlet gas pressure is too low

1. Manifold pressure is too low

2. Burner orifice is clogged

REMEDY

1. Replace pilot assembly

2. Replace pilot assembly

3. Reconnect ignitor cable

4. Free ignitor cable if pinched

by any metal or tubing. Keep

ignitor cable dry

5. Replace ignitor cable

6. Replace piezo ignitor valve

assembly

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in 30

seconds

3. Wait one minute for safety

interlock system to reset.

Repeat ignition operation.

4. Hand tighten until snug, then

tighten 1/4 turn more

5. A) Replace propane/LP gas

cylinder

B) Clean ODS/pilot (see

Cleaning and Maintenance

,

page 7) or replace ODS/pilot

assembly

6. Replace pilot assembly

7. Replace control valve

1. Clean burner orifice (see Clean-

ing and Maintenance, page 7)

or replace burner orifice

2. Replace propane/LP gas

cylinder

1. Replace propane/LP gas

cylinder

2. Clean burner orifice (see Clean-

ing and Maintenance, page 7)

or replace burner orifice

OBSERVED PROBLEM

When ignitor button is actuated,

there is no spark at ODS/pilot

ODS/pilot lights but flame

goes out when control knob is

released

Burner does not light after ODS/

pilot is lit

Delayed ignition of burner

Advertising