Voodoo Lab Pedal Power MONDO User Manual

Page 7

Advertising
background image

- 5 -

DIP Switches

On the bottom of MONDO is an 8 position DIP switch numbered 1-8. These

switches correspond to outputs labeled 1-8 and select the output voltage. The

switches should be in the OFF position for standard 9V operation. Setting a

switch to ON enables the alternate voltage.

Switches 1-4. These select 12V at 60mA. This is commonly used for battery

operated Boss pedals which specify the ACA type power supply.

Switches 5-6. These select unregulated 12V at 250mA. Since it is unregulated,

actual voltage will vary from 12V at 250mA up to about 16V when lightly loaded.

The most common use is for Line 6 modeling pedals such as DL4 and MM4.

Switches 7-8. These enable SAG controls. When switched on, the voltage is

determined by the SAG control. You can adjust the voltage from 9V down to 4V

to simulate a dying battery.

Advertising